Greek
technissis.gr > Products > Leister > Tools > LE 10000 DF
LE 10000 DF

  • Easy to integrate into existing air systems
  • Suitable for recycling air
  • Simple and safe fixture options
  • No integrated power electronics
The latest generation of double-flange air heaters is specially designed to be used in hot-air recirculation mode. Depending on the air inlet and air outlet temperature, a massive amount of energy can be saved by “recycling“ hot-air. On the inlet side, the device can easily tolerate temperatures up to 160°C
Specification
  LE 10000 DF -
3 x 400 V /
11 kW
LE 10000 DF -
3 x 400 V /
17 kW
LE 10000 DF -
3 x 400 V /
5.5 kW
Article No.:   114.555 116.135 115.571
Attribute Unit Value Value Value
Voltage V~ 3 x 400 3 x 400 3 x 400
Power W 11000 17000 5500
Max. air outlet temperature °C 650 650 650
Min. air volume (20°C) Nl/min 810 1300 400
Max. air inlet temperature °C 160 160 160
Max. ambient temperature °C 100 100 100
Size (L × ∅) mm 165 × 146 165 × 146 165 × 146
Weight kg 3.4 3.4 3.4
Conformity mark  
Protection class I  

Similar products
LE 10000 DF-R LE 5000 DF< LE 5000 DF-R
LE 10000 DF-R LE 5000 DF LE 5000 DF-R
LE 10000 DF-R HT (up to 900 °C) LE 10000 DF HT (up to 900 °C)  
LE 10000 DF-R HT (up to 900 °C) LE 10000 DF HT (up to 900 °C)