Suitable for Leister air heaters |
|
LHS SYSTEM, LE MINI SENSOR, Universally deployable temperature regulator |
Ready to use with preconfigured parameter set |
|
(for LHS SYSTEM, MISTRAL SYSTEM, HOTWIND SYSTEM, VULCAN SYSTEM) |
Configuration with PC and programming cable |
|
|
Accuracy |
|
> 0.2 % of scale value at 25 °C |
Temperature sensor / input |
|
Type K, PT100, screw connectors |
Alarm output |
|
2 independently configurable alarms Output at 2 floating relay contacts Screw connector |
Mains connection lead |
|
Without lead, screw connectors |
Mechanics |
|
Regulator for front panel integration, with cut-out 45 × 45 mm |